Appendix D 719
Softkey Functions
System Menu
D. Softkey Functions
Multiport Test Set
Setup
Displays softkeys for setting the E5091A control.
Test Set 1 Displays the model selected for test set 1 (ID=1)
Port 3 Displays softkeys for selecting a test port of the E5091A to which you want to connect port 3.
R1+ Selects test port R1+.
:SENS{1-16}:MULT1:PORT3 R1
R2+ Selects test port R2+.
:SENS{1-16}:MULT1:PORT3 R2
R3+ Selects test port R3+.
Selects test port R2+.
R4+
*1
Selects test port R4+.
Selects test port R2+.
Cancel Returns to the softkey display screen one level higher.
Port 4 Displays softkeys for selecting a test port of the E5091A to which you want to connect port 4.
R1- Selects test port R1-.
:SENS{1-16}:MULT1:PORT4 R1
R2- Selects test port R2-.
:SENS{1-16}:MULT1:PORT4 R2
R3- Selects test port R3-.
:SENS{1-16}:MULT1:PORT4 R3
R4-
*1
Selects test port R4-.
:SENS{1-16}:MULT1:PORT4 R4
Cancel Returns to the softkey display screen one level higher.
Port 5
*1
Displays softkeys for selecting a test port of the E5091A to which you want to connect port 5.
X1 Selects test port X1.
:SENS{1-16}:MULT1:PORT5 X1
X2 Selects test port X2.
:SENS{1-16}:MULT1:PORT5 X2
Cancel Returns to the softkey display screen one level higher.
Port 6
*1
Displays softkeys for selecting a test port of the E5091A to which you want to connect port 6.
Y1 Selects test port Y1.
:SENS{1-16}:MULT1:PORT6 Y1
Y2 Selects test port Y1.
:SENS{1-16}:MULT1:PORT6 Y2
Cancel Returns to the softkey display screen one level higher.
Port 7
*1
Displays softkeys for selecting a test port of the E5091A to which you want to connect test port 7.
Z1 Selects test port Z1.
:SENS{1-16}:MULT1:PORT7 Z1
Z2 Selects test port Z2.
:SENS{1-16}:MULT1:PORT7 Z2
Cancel Returns to the softkey display screen one level higher.
Control Lines Displays softkeys for setting HIGH/LOW of control lines.
Line 1 Sets HIGH/LOW of line 1.
:SENS{1-16}:MULT1:OUTP
Line 2 Sets HIGH/LOW of line 2.
:SENS{1-16}:MULT1:OUTP
Line 3 Sets HIGH/LOW of line 3.
:SENS{1-16}:MULT1:OUTP
Line 4 Sets HIGH/LOW of line 4.
:SENS{1-16}:MULT1:OUTP
Line 5 Sets HIGH/LOW of line 5.
:SENS{1-16}:MULT1:OUTP
Line 6 Sets HIGH/LOW of line 6.
:SENS{1-16}:MULT1:OUTP
Line 7 Sets HIGH/LOW of line 7.
:SENS{1-16}:MULT1:OUTP
Line 8 Sets HIGH/LOW of line 8.
:SENS{1-16}:MULT1:OUTP
Return Returns to the softkey display screen one level higher.
Return Returns to the softkey display screen one level higher.
Test Set 2 Displays the model selected for test set 2.
Return Returns to the softkey display screen one level higher.
Key Operation Function SCPI Command