AT-GS900M Series CLI Reference
Section III: Layer 2 Switching 235
DISABLE SWITCH PORT FLOW
Syntax
disable switch port=
port_list
|all flow
Parameters
port_list
Specifies a list of ports. To specify multiple ports, use a comma (,)
to separate them. To specify a range of ports, use a hyphen (-).
all
Specifies all the switch ports.
Description
Use this command to disable flow control on switch ports. By default, flow
control is enabled.
To disable flow control on a trunk port, you must specify all trunk ports in a
trunk group.
Confirmation Command
“SHOW SWITCH” on page 267
Example
The following command disables flow control on port 3:
Manager > disable switch port=3 flow