AT-GS900M Series CLI Reference
Section I: Getting Started 53
SET SYSTEM SFP-TEMPTHRESHOLD
Syntax
set system sfp-tempthreshold=
temperature
Parameter
temperature
Specifies the temperature threshold. The value must be 40, 45, or
50⁰C.
Description
Use this command to set the temperature threshold for the SFP modules.
When the internal temperature of the SFP module exceeds the
temperature threshold, the switch sends alarm messages such as SNMP
traps and log messages.
By default, the temperature threshold for the GS908M V2 and GS924M V2
switches is 45⁰C and one for the GS916M V2 switch is 50⁰C.
Here are the guidelines for setting the temperature threshold for the SFP
module:
When the AT-SPLX40, AT-SPZ80, AT-SPBD80-A, or AT-SPBD80-
B SFP module is attached to the GS908M V2 or GS924M V2
switch, the temperature threshold must be 45⁰C.
This command is available only for the GS908M V2, GS916M V2,
and GS924M V2 switches.
Confirmation Command
“SHOW SYSTEM” on page 58
Example
The following command specifies the temperature threshold for SFP
modules to 40⁰C:
manager > set system sfp-tempthreshod=40