AT-GS900M Series CLI Reference
Section III: Layer 2 Switching 263
SET SWITCH STORMDETECTION
Syntax
set switch stormdetection port[=
port_list
|all]
[lowrateaction=portdisable|linkdown|bcdiscard|none]
[highrateaction=portdisable|linkdown|bcdiscard|none]
[lowratethreshold=
rate
] [highratethreshold=
rate
]
[blocktimeout=
timeout
|none]
[frametype=broadcast|multicast|all]
[framesize=
framesize
|auto]
Parameters
port_list
Specifies a list of ports. To specify multiple ports, use a comma (,)
to separate them. To specify a range of ports, use a hyphen (-).
all
Specifies all the switch ports.
lowrateaction
Specifies an action when the port detects the loop. The port stops
the action after the time specified by the blocktimeout parameter
has passed.
portdisable
The port is disabled when the loop is detected. This is the default
setting.
linkdown
Specifies that the port is disconnected when the loop is detected.
bcdiscard
Specifies that the port stops receiving broadcast frames when the
loop is detected.
none
Specifies that the port takes no action. However, the switch issues
log messages.
interval
Specifies the interval of sending a Loop Detection Frame (LDF) in
seconds. The default setting is 120 seconds.
secure
Specifies an action when the port receives an LDF.

Table of Contents

Other manuals for Allied Telesis AT-GS908M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allied Telesis AT-GS908M and is the answer not in the manual?

Allied Telesis AT-GS908M Specifications

General IconGeneral
BrandAllied Telesis
ModelAT-GS908M
CategorySwitch
LanguageEnglish

Related product manuals