EasyManua.ls Logo

Allied Telesis AT-GS908M - Disable System Fan-Startstop-Alarm

Allied Telesis AT-GS908M
542 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AT-GS900M Series CLI Reference
Section I: Getting Started 41
DISABLE SYSTEM FAN-STARTSTOP-ALARM
Syntax
disable system fan-startstop-alarm
Parameters
None
Description
Use this command to stop sending alarm messages when the fan starts
and stops. Alarm messages are:
SNMP trap
Syslog message
Log message
Event message
By default, when the fan starts and stops, the switch sends alarm
messages.
Confirmation Command
“SHOW SYSTEM” on page 58
Example
The following example disables the fan and alarm messages:
manager > disable system fan-startstop-alarm