Chapter 16: Forwarding Database (FDB) Commands
296 Section III: Layer 2 Switching
ENABLE SWITCH AGEINGTIMER
Syntax
enable switch agingtimer
Parameters
None
Description
Use this command to enable the FDB aging timer. When the FDB aging
timer is enabled, the dynamic entires of FDB are expired and deleted. By
default, the FDB aging timer is enabled.
Confirmation Command
“SHOW SWITCH FDB” on page 299
Example
The following command enables the FDB aging timer:
Manager > enable switch agingtimer