Maintenance-Object Repair Procedures
555-233-143
8-296 Issue 1 May 2002
6 FAIL A previously established loop around was not released.
1. Run reset board UUCSS.
2. Retry the command up to 3 times at 1-minute intervals.
3. If this test continues to fail, replace the ATM-TRK circuit pack.
4. Rerun test board UUCSS long.
PASS The non-optical parts of the ATM-TRK circuit pack are functioning properly.
0NO
BOARD
ATM-TRK circuit pack not found
1. Check the error log for Error 125 (wrong board) or Error 131 (no board),
and correct as necessary.
2. Check that the board is properly translated and inserted.
3. Check for Error 1538 (hyperactivity), and run reset board UUCSS if
necessary.
4. Rerun test board UUCSS long.
5. If the test fails, replace the board, and rerun test board UUCSS long.
Table 8-129. ATM Board Framer Loop-Around Test (#1260) — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page