EasyManua.ls Logo

Avaya S8700 - Page 1080

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance-Object Repair Procedures
555-233-143
8-358 Issue 1 May 2002
Notes:
a. Errors of this type indicate violations of the ISDN-BRI signaling protocol;
timers associated with certain layer-3 messages have expired before a
required response was received. In the following table, the aux data field
indicates what timer has just expired. (For more information, refer to the
Avaya ISDN-BRI Specification.
3329
(k)
Any Signaling Link
Status
(626)
WARNING MAJOR/
WARNING
2
OFF
3584 0,1 None
3585-
3839(i)
0 None
3840-
4095
(m) (n)
0 None
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
2. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command.
Aux Data Timer Type
2 First T303 (SETUP timer)
3 Second T303 (SETUP timer)
4 T305 (DISConnect timer)
5 First T308 (RELease timer)
6 Second T308 (RELease timer)
10 T316 (RESTart timer)
12 T309 (Layer-2 Failure timer)
16 TM100 (Management Information
message Timer 1)
17 TM200 (Management Information
message Timer 2)
102 TASAI (ASAI Routing timer)
Table 8-152. BRI-SET/ASAI-ADJ Error Log Entries Continued
Error
Type
Aux
Data
Associated
Tes t
Alarm
Level
BBRI-SET
ASAI-ADJ
ASAI-ADJ
ATT-ADJ
LGATE-|AJ
ATTE-AJ
On/
Off
Board Test to Clear Value
Continued on next page

Table of Contents