EasyManua.ls Logo

Avaya S8700 - Page 1085

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BRI-SET, ASAI-ADJ, BRI-DAT
Issue 1 May 2002
8-363555-233-143
m. Certain ISDN-BRI cause codes are logged by switch software. The cause
code can be determined from the following formula:
If the error type is greater than 3968, then the ISDN-BRI cause code is
equal to the error type minus 3968. This code was sent to the endpoint by
the switch.
If the error type is less than 3968, then the ISDN-BRI cause code is equal
to the error type minus 3840. This code was sent to the switch by the
endpoint.
A description of the various ISDN-BRI cause values is contained in Table
8-154 on page 8-364. This table also contains recommended system
technician actions associated with the cause value. Further information
can also be found in the Avaya ISDN-BRI Specification (801-802-100). In
addition, the Aux Data field of the Error Log entry contains additional
diagnostic information.
n. Error 3847 indicates that sets on the port do not support level 3
initialization. Consult the Set Service documentation
o. For the Error 2567 indicates that the version of ASAI is not supported,
check version of the software running on the ASAI or Avaya adjunct.
79 SERVICE OR
OPTION NOT
IMPLEMENTED
Requested service or option (or combination of selected
options) is not supported (implemented) in switch or the
adjunct.
1. Consult switch and adjunct documentation to
determine ASAI service and options supported by
both switch and adjunct. Re-administration of the
switch-administered capabilities (see Customer
Optional Feature form) or those of the adjunct may
be necessary to correct the problem.
2. If step 1 does not provide the set of desired services
due to deficient implementation, escalate the
problem to the next tier.
87 Internal switch
audit
There is an inconsistency in switch data records.
1. There is no action needed since the switch has
corrected the data inconsistency.
2. If a number of these errors continue to occur, then
escalate to next tier.
Table 8-153. ASAI CAUSE VALUES Continued
Error
Code Test Result Description / Recommendation
Continued on next page