CLSFY-PT (Call Classifier Port)
Issue 1 May 2002
8-433555-233-143
Tone Detector Audit/Update Test (#43)
This test performs a sanity audit on the CLSFY-PT (Call Classifier Port).
Table 8-177. Test #43 Tone Detector Audit/Update Test
Error
Code
Tes t
Result Description / Recommendation
none ABORT The system was not able to allocate the resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Hardware audit failed.
1. Issue these commands in order: busyout board, reset board, release
board. The board reset is required to reload on-board RAM associated
with the TN744s DSPs. This takes all 8 Tone Detector ports out of service
for a few seconds. Only 4 of the 8 would be out of service due to the
alarm. (There are five Tone Detectors on each of the two DSPs.) Other
than the unlikely potential of running out of Tone Detector resources in the
switch, there is no other effect when the board is reset.
2. Test the board (test board UUCSS long).
3. If the test still fails, replace the board.
PASS The call classifier port has passed the sanity inquiry.