Maintenance-Object Repair Procedures
555-233-143
8-450 Issue 1 May 2002
1020 ABORT The DS1 Interface circuit pack is out-of-service.
1. Look for DS1-BD/UDS1-BD errors in the Hardware Error Log. If present,
see the appropriate DS1-BD/UDS1-BD (DS1/UDS1 Trunk circuit pack).
2. Retry the command.
2012 ABORT The test was aborted due to an internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABORT Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
2000 FAIL Response to the seizure message was not received within the allowable time
period.
1. Enter the list configuration board UUCSS command. If the circuit pack
is a TN767B vintage 8 or 9, a failure of test 314 causes a subsequent
failure of test 7 due to a firmware bug. Eventually, the board and all of its
ports will be taken out of service and extraneous on-board alarms will be
generated. Replace the circuit pack with a TN767C V3 or later.
2. Verify that the
Trunk Type field on the Trunk Administration screen
matches the trunk type administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error log. If present,
see the DS1-BD (DS1 trunk circuit pack) maintenance documentation or to
the UDS1-BD (UDS1 trunk circuit pack) maintenance documentation.
4. Retry the command at 1-minute intervals up to 5 times.
2053 FAIL At least one of the following errors was found on the DS1 circuit pack: Loss of
signal (1281), Blue alarm (1793), Red alarm (2049), Yellow alarm (2305), or
Hyperactivity (1537).
1. Look for these error types in the hardware error log, and then follow the
procedures given in the maintenance documentation that is appropriate for
the error type that was found.
FAIL The trunk cannot be seized for an outgoing call. This could cause in-line
failures to be reported against the trunk (no answer would report error type 257
with auxiliary data 57487 in the error log).
1. Verify the
Trunk Type field on the trunk administration screen form
matches the trunk type administered on far-end switch.
2. Look for DS1-BD/UDS1-BD errors in Error Log. If present, see‘‘DS1-BD
(DS1 Interface Circuit Pack)’’.
3. Retry the command at 1-minute intervals up to 5 times.
PASS The trunk can be seized for an outgoing call.
Table 8-182. Test #314 DS1 CO Dial Tone Seizure Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page