CO-DS1 (DS1 CO Trunk)
Issue 1 May 2002
8-451555-233-143
0NO
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an incorrect
board is inserted, an insane board is inserted, or the board is hyperactive.
1. Verify that the boards translations are correct. Use the list config
command, and resolve any problems that are found.
2. Issue the busyout board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command.
This should re-establish the linkage between the internal ID and the port. If
not, dispatch to verify that a valid board is inserted.
Hyperactivity causes some special problems with the sequence suggested
above. If the ports are translated after issuing the list config command but the
Vintage field reports that there is no board (when there really is a board),
then the busyout board and the release busy board commands will not work
(even though the reset board command will work). The software will put the
hyperactive board back in service after the hyperactivity clears.
Table 8-182. Test #314 DS1 CO Dial Tone Seizure Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page