EasyManua.ls Logo

Avaya S8700 - Page 1177

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CO-TRK (Analog CO Trunk)
Issue 1 May 2002
8-455555-233-143
Notes:
a. These are in-line errors that have no specific test associated with them.
Refer to the following table for an explanation and appropriate action.
b. This is a software audit error that does not indicate any hardware
malfunction. Run short test sequence, and investigate associated errors.
c. This error type indicates that the circuit pack has been removed or has
been insane for at least 11 minutes. To clear the error, reinsert or replace
the circuit pack.
1537 Dial Tone test (#0) MAJOR
MINOR
WARNING
2
OFF test port UUCSSpp l r 2
1793 Looparound and
Conference test (#33)
MAJOR
MINOR
WARNING
2
ON test port UUCSSpp l r 3
2049 NPE Cross Talk test
(#6)
MAJOR
MINOR
WARNING
2
ON test port UUCSSpp l r 3
2561 (d) 57345 None
2817 (a) 57360 None
2817 (a) 57393 None
2817 (d) 57484 Dial Tone test(#0) MAJOR
MINOR
WARNING
OFF test port UUCSSpp l r 1
3073 (d) 57376 None
3329 (d) 57408 None
3329 (d) 57484 Dial Tone test (#0) MAJOR
MINOR
WARNING
OFF test port UUCSSpp l r 1
3585 (d) 57424 None
3840 (f) 8000 Transmission tests
(ATMS)(#844-848)
OFF test analog-testcall
3841 (f) Transmission tests
(ATMS)(#844-848)
MINOR OFF test analog-testcall
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
2. Major alarms may be downgraded to Warning alarms based on the value used in the set options command.
Table 8-183. CO Trunk Error Log Entries Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page

Table of Contents