DID-DS1 (Direct Inward Dial Trunk)
Issue 1 May 2002
8-505555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. Error Type 1—DS1 Interface circuit pack detects a hardware error on the
DS1 DID trunk. The Aux Data field indicates the following:
Table 8-204. DID-DS1 Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0Any Any Anytest trunk grp#/mbr#
1 (a) Any
15 (b) Any Port Audit and Update
test (#36)
18 (c) WARNING OFF release trunk grp#/mbr#
130 (d) None WARNING ON test trunk grp#/mbr#
257 (e) 57474
57473
513 (f) 57392 MAJOR
MINOR
2
2. This alarm will only be raised when the System-Parameter Country form has the Base Tone Generator field
set to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are out of service,
then the alarm will be upgraded to a MAJOR alarm.
769 (g) 57393 MAJOR
MINOR
2
1281 Conference Circuit test
(#7)
MINOR
WARNING
3
3. Major alarms may be downgraded to Warning alarms based on the value used in the set options command.
ON test trunk grp#/mbr# l r 4
1537 NPE Crosstalk test
(#6)
MINOR
WARNING
3
ON test trunk grp#/mbr# l r 3
1793 (h) test board UUCSS l
2305 (i) 50944 None MAJOR
MINOR
2
OFF
3840 (j) Port Audit and Update
test (#36)
57476 On-hook before wink
57477 On-hook before ready to receive digits
57485 Wink too short for valid signal