DID-DS1 (Direct Inward Dial Trunk)
Issue 1 May 2002
8-513555-233-143
Port Audit and Update Test (#36)
This test sends port-level translation data from the switch processor to the DS1
Interface circuit pack to assure that a trunks translations are correct. The port
audit operation verifies the consistency of the current state of the trunk as kept in
the DS1 Interface circuit pack and in switch software.
Table 8-207. Test #36 Port Audit and Update Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT The port may be busy with a valid call.
1. Issue display port UUCSSpp to determine the trunk group/member
number of the port. Use the status trunk command to determine the
service state of the port. If the port is in use, wait until it is idle before
testing.
2. If the port status is active but the port is idle (no calls), check the error log
for Error Type #1025. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1006 ABORT The test was aborted because the trunk is out of service.
1. Use status trunk to verify that the trunk is out of service.
2. If the trunk is out of service, determine why.
3. To put the trunk back in service, issue the release trunk command. Retry
the test.
2000 ABORT Response to the test was not received in the allowable time period.
2100 ABORT Could not allocate resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page