Loading...
Maintenance-Object Repair Procedures
555-233-143
8-512 Issue 1 May 2002
PASS The port can correctly conference multiple connections. Investigate
user-reported troubles on this port using other port tests and by examining
station, trunk, or external wiring.
0NO
BOARD
The test could not relate the internal ID to the port. This could be due to
incorrect translations, no board is inserted, an incorrect board is inserted, or an
insane board is inserted.
1. Verify that the boards translations are correct. Use the lIst config
command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, issue the busyout
board command.
3. Issue the reset board command.
4. Issue the release busy board command.
5. Issue the test board long command.
This should re-establish the link between the internal ID and the port. If
not, check to see that there is a valid board inserted.
Table 8-206. Test #7 Conference Circuit Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page