1018 ABORT The test was disabled via translation. Determine why the test has been
disabled before you enable it.
1. Verify that the Maintenance Test field on the Trunk Administration
screen is set to
n. To enable the test, change the trunk administration and
enter y for this field.
2. Repeat the test.
1020 ABORT The test did not run due to a previously existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the previously existing error.
2000 ABORT Response to the test was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2053 ABORT At least one of the following errors is found on the DS1 circuit pack (DS1-BD or
UDS1-BD):
1281Loss of signal, 1793Blue Alarm, 2049Red Alarm, 2305Yellow
Alarm, 1537Hyperactivity
1. Resolve any of the above error types.
Any FAIL The NPE of the tested port did not conference the tones correctly. This can
cause noisy and unreliable connections.
1. Enter list configuration board UUCSS. The circuit pack must be a
TN767C V3 or later. The error log may have Error Type #1281.
2. Test every administered trunk on the board. If one fails, this could be an
off-board problem (such as an incoming seizure or an off-hook port seizure
during the test). Retest the board.
3. If every port fails, a -5V power problem is indicated. Check CARR-POW.
4. If several ports fail, resolve any TONE-BD or TONE-PT errors and rerun
the test.
5. If the retry passes and troubles are reported, coordinate isolation with the
CO. Make sure that the switch, the CO, and any NTCE equipment (the
CSUs) have the correct administration.
6. Replace the circuit pack.
Table 8-206. Test #7 Conference Circuit Test Continued