Maintenance-Object Repair Procedures
555-233-143
8-516 Issue 1 May 2002
DID Trunk Testing
The system uses four tests of on-board circuitry to diagnose the health of the
trunk. These are described in the following sections. Additionally, in-line testing
which can generate errors, is performed while a call is in progress. See the Error
Log table for a description of these errors. These errors may be reproduced by
placing a call on the trunk and checking the Hardware Error Log.
Problems detected during signaling may be caused by off-board faults in the CO
switch or connections for which a Warning alarm is raised.
Before a maintenance test can be run on a port, the port must be idle. If an
incoming call seizes a port that is being tested, the test will abort and the incoming
call will proceed.
For transmission and signaling standard specification, refer to Digital PBX
Standards, RS4648.
Ports Out-of-Service without Errors or Alarms
A common trouble on DID trunks that produces no errors or alarms occurs when
the CO busies out (disconnects) the port. This situation occurs when the CO
thinks there are problems with the DID port. In this case, no incoming calls will be
possible through this port. This may result in complaints from outside callers
trying unsuccessfully to call in. This problem can be diagnosed by listing
measurements on lightly used trunks. If a particular port is detected as idle, a call
to the CO will be necessary to get the connection back in service.
Error Log Entries and Test to Clear Values
Table 8-208. DID Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
0 Any Any Any test port UUCSSpp sh r 1
1 (a) Any None WARNING OFF
1 (b) 57476 None WARNING OFF
1 (c) 57477 None WARNING OFF
1 (d) 57483 None WARNING OFF
15 (e) Any Port Audit Update
(#36)
18 0 busyout trunk
grp/mbr
WARNING OFF release trunk grp/mbr
130 (f) None WARNING ON test trunk grp/mbr