DID-TRK (Direct Inward Dial Trunk)
Issue 1 May 2002
8-517555-233-143
Notes:
See also the preceding section on trunk problems without errors or alarms.
a. This condition occurs when the tone detector times out waiting for digits.
Change wink/immediate-start parameter to wink/immediate-start and
rotary/tone-dial parameters.
1. Verify trunk administered wink/immediate-start parameter.
2. Test trunk using BUTT set.
3. Refer problem to CO.
b. Rotary dial before wink — This condition occurs when the CO starts dialing
before the PBX sends wink on a wink-start trunk.
1. Verify trunk administered wink/immediate-start parameter.
2. Refer problem to CO.
257 (g) 57472 None WARNING OFF
257 (h) 57473 None WARNING OFF
257 (i) 57474 None WARNING OFF
257 (j) 57475 None WARNING OFF
513 (k) 57392 None MINOR
WARNING
2
OFF
510 (l) 57393 None
769 Any Port Diagnostic (#35) MINOR
WARNING
2
ON test port UUCSSpp r 3
1025 Looparound and
Conference (#33)
MINOR
WARNING
2
ON test port UUCSSpp l r 3
1281 NPE Crosstalk (#6) MINOR
WARNING
2
ON test port UUCSSpp l r 3
1537 Any Port Diagnostic (#35) MAJOR
MINOR
WARNING
2
OFF test port UUCSSpp r 3
1793 (m) 57489 None None
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
2. Major alarms may be downgraded to Warning alarms based on the value used in the set options command.
Table 8-208. DID Trunk Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page