Maintenance-Object Repair Procedures
555-233-143
8-524 Issue 1 May 2002
3 FAIL The nonreflective 1004-Hz tone test of the port failed. An echo was detected
from the port. Poor-quality transmission was detected to or from the port.
The problem may be off-board.
7 The conference capabilities of the port failed. Poor-quality transmission was
detected to or from the port. The problem may be off-board.
129 The reflective 404-Hz tone test failed. Poor-quality transmission was detected
to or from the port. The problem may be off-board.
131 The reflective 1004-Hz tone test failed. Poor-quality transmission was
detected to or from the port. The problem may be off-board.
133 The reflective 2804-Hz tone test failed. Poor-quality transmission was
detected to or from the port. The problem may be off-board.
!
CAUTION:
The port may still be operational, or the fault may be off-board
(connections or CO). Off-board problems include incoming
seizures or off-hook port seizures during the test and, perhaps,
noise induced by adjacent electric power lines. The test may be
disabled from trunk administration Test field. This turns off all
testing for that trunk group except for tests 6 and 36.
Table 8-210. Test #33 Loop-Around and Conference Circuit Test Continued
Error
Code
Te s t
Result Description / Recommendation
Continued on next page