Maintenance-Object Repair Procedures
555-233-143
8-544 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Table 8-219. Digital Line Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to the appropriate tests
description and follow the recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 (a) 40987,
1 20
None WARNING OFF
18 (b) 0 busyout port
UUCSSpp
WARNING OFF rel port UUCSSpp
130 (c) None WARNING ON test port UUCSSpp sh
257 (d) 40971 None
513 0 Station (Digital) Audits
test (#17)
WARNING OFF test port UUCSSpp sh r 6
767 (e) 40964 None WARNING OFF
769 (f) 40963
40988
None WARNING OFF
1026 (g) NONE WARNING OFF
1281 Any Station (Digital) Audits
test (#17)
WARNING OFF test port UUCSSpp sh r 4
1537 (h) 40968 None WARNING OFF
1793 Voice and Ctrl. Local
Loop test (#13)
MINOR/
WARNING
2
2. Major alarms may be downgraded to Warning alarms based on the value used in the set options command.
ON test port UUCSSpp l r 3
2049 NPE Crosstalk test
(#9)
MINOR/
WARNING
2
ON test port UUCSSpp l r 3
2304 (i) None
2305 (j) 32770,
40969
None
2817 (k) Any None OFF
3585 (l)
3840 (m) 40965,
40989
None
3841 (n) 41029 None

Table of Contents