DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 May 2002
8-563555-233-143
Error Log Entries and Test to Clear Values
Table 8-226. DS1 DIOD Trunk Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test trunk grp/mbr
1(a) 57408
1(a) 57487
57476
57477
57485
15 (b) Any Port Audit and
Update test (#36)
18 (c) 0 busyout trunk
grp/mbr
WARNING OFF release trunk grp/mbr
130 (d) None WARNING ON test trunk grp/mbr>
257 (e) 57392 DS1 CO Dial Tone
Seizure test (#314)
MAJOR
MINOR
2
2. This alarm is only raised when the System-Parameter Country form has the Base Tone Generator field set
to 4 (Italy). This alarm will be a MINOR alarm unless 75% or more trunks in this trunk group are out of service,
then the alarm will be upgraded to a MAJOR alarm.
OFF
513 (f) 57393 DS1 CO Dial Tone
Seizure test (#314)
MAJOR
MINOR
2
OFF
769 (g) 57484
1025 (h) 51200
1025 DS1 CO Dial Tone
Seizure test (#314)
MINOR
WARNING
3
3. Major alarms may be downgraded to Warning alarms based on the value used in the set options command.
OFF test trunk grp/mbr r 2
1281 Conference Circuit
test (#7)
MINOR
WARNING
3
ON test trunk grp/mbr l r 4
1537 NPE Crosstalk test
(#6)
MINOR
WARNING
3
ON test trunk grp/mbr l r 3
1793 (i) test board UUCSS l
2049 (j) 57473
57474
57475
2305 (k) 50944
2562 (l) 16665
2817 (m) 52992
3840 (n) Port Audit and
Update test (#36)