DIOD-TRK (DIOD Trunk)
Issue 1 May 2002
8-575555-233-143
Error Log Entries and Test to Clear Values
Notes:
a. These are in-line errors that have no specific test associated with them.
See Table 8-233 for an explanation and appropriate action.
b. This is a software audit error and does not indicate any hardware
malfunction. Run the short test sequence, and investigate associated
errors.
Table 8-232. DIOD Trunk Error Log Entries
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board
Test to Clear
Va lue
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test port sh
15 (b) any Port Audit Update test (#36)
18 0 busyout trunk grp/mbr WARNING release trunk
769 (a) 57392 None MAJOR
MINOR
WARNING
2
2. Major alarms on this MO may be downgraded to Warning alarms based on the value used in the set options
command. If the Minor alarm is not downgraded by the set-options values, the Minor alarm is upgraded to a
Major alarm if 75 percent of the trunks in this trunk group are alarmed.
ON
1537 Dial Tone test (#0) MAJOR
MINOR
WARNING
2
ON test port long r 2
1793 Looparound and Conference
test (#33)
MAJOR
MINOR
WARNING
2
ON test port long r 3
2049 NPE Cross Talk test (#6) MAJOR
MINOR
WARNING
2
ON test port long r 3
2561 (a,d) 57345 None
2817 (a,e) 57393 None
3073 (a,c) 57376 None
3073 (a,c) 57424 None
3585 (a,c) 57424 None