Maintenance-Object Repair Procedures
555-233-143
8-668 Issue 1 May 2002
Clearing Firmware Errors
DS1 CONV error reports are generated by firmware autonomously, they are not
associated with technician-demanded tests. Therefore, the test board clear
command does not affect the error status known by the DS1 CONV firmware. To
clear every on-board firmware-detected error unconditionally, execute the clear
firmware-counters command.
Error Log Entries and Test to Clear Values
Table 8-263. DS1 Facility Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board SAT Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0 Any Any Any test ds1-facility UUCSSf sh r 1
1 (a) Failure Audit #949 MAJOR ON test board UUCSS sh r 1
18 (b) 0 busyout
ds1-facility
UUCSSf
WARNING OFF release ds1-facility UUCSS
257 (c) Failure Audit #949 MINOR ON test board UUCSS sh r 1
513 (d) 1 Failure Audit #949 MINOR OFF test board UUCSS sh r 1
513 (d) 2 Failure Audit #949 MINOR OFF test board UUCSS sh r 1
856 (e) DS1 Facility Query
for Slips/Misframes
#972
MINOR OFF none
1025 (f) Failure Audit #949 MAJOR
2
2. These failures are logged as a WARNING alarm when the error is first reported. The alarm severity is raised to a
MAJOR in 15 minutes if the problem persists.
OFF test board UUCSS sh r 1
1281 (g) None Failure Audit #949 MAJOR
2
OFF test board UUCSS sh r 1
1281 (g) 1 Failure Audit #949 MAJOR
2
OFF test board UUCSS sh r 1
1281 (g) 2 Failure Audit #949 MAJOR
2
OFF test board UUCSS sh r 1
1537 (h) Failure Audit #949 MAJOR
2
OFF test board UUCSS sh r 1
1793 (i) Failure Audit #949 MAJOR
2
OFF test board UUCSS sh r 1
2065 (j) DS1 Facility Query
for Slips/Misframes
#972
MINOR OFF none
2305 (k) Failure Audit #949 MAJOR OFF test board UUCSS sh r 1
2561 (l) Failure Audit #949 MINOR
3
3. This failure is logged as a WARNING alarm when the error is first reported. The alarm severity is raised to a
MINOR in 15 minutes if the problem persists.
OFF test board UUCSS sh r 1