Maintenance-Object Repair Procedures
555-233-143
8-714 Issue 1 May 2002
FAIL TN574 DS1 facilities connectivity loop-back test failed.
1 FAIL TN1654 near-end DS1 facility A is connected to far-end DS1 facility B.
2 FAIL TN1654 near-end DS1 facility A is connected to far-end DS1 facility C.
3 FAIL TN1654 near-end DS1 facility A is connected to far-end DS1 facility D.
10 FAIL TN1654 near-end DS1 facility B is connected to far-end DS1 facility A.
12 FAIL TN1654 near-end DS1 facility B is connected to far-end DS1 facility C.
13 FAIL TN1654 near-end DS1 facility B is connected to far-end DS1 facility D.
20 FAIL TN1654 near-end DS1 facility C is connected to far-end DS1 facility A.
21 FAIL TN1654 near-end DS1 facility C is connected to far-end DS1 facility B.
23 FAIL TN1654 near-end DS1 facility C is connected to far-end DS1 facility D.
30 FAIL TN1654 near-end DS1 facility D is connected to far-end DS1 facility A.
31 FAIL TN1654 near-end DS1 facility D is connected to far-end DS1 facility B.
32 FAIL TN1654 near-end DS1 facility D is connected to far-end DS1 facility C.
55 FAIL TN1654 DS1 CONV packet facility is down and can’t send loop-up message to
the far end.
1. Enter display errors and follow the associated repair procedures for any
DS1-FAC errors on the DS1 facilities at both ends of the DS1 CONV
complex. If an alarm exists on a DS1 facility, then this test will fail.
2. Check the DS1 connections, both circuit packs should have their DS1
facilities connected identically.
3. Check the DS1 Converter Measurements Report to see if there are
facilities with excessive errors, execute command list measurements
ds1-facility summary. If there are facilities with excessive errors, execute
the Far-End Internal Loopback test (#797) via the test ds1-facility
UUCSSf long command on those facilities, and follow repair procedures
described for the test.
4. Both circuit packs may not have the same translation information. Run the
Board Options Audit test (#795) via the test board UUCSS short
command for both circuit packs in the DS1 CONV complex to send the
options, and check the results of this audit test. This test will not pass until
the audit test problems are resolved.
PASS DS1 facility connections are correct.
0NO
BOARD
The system software found no board.
1. Reset the board.
2. Remotely retry the command.
Table 8-276. Test #790 DS1 Facilities Connectivity Loop-Back Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page