E-DIG-STA (Emulated Digital Line)
Issue 1 May 2002
8-735555-233-143
1392 ABORT This is currently a TTI port, and the test cannot execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a
t for the port).
2. If either list config or display port indicates that the port is not a TTI port,
escalate the problem. If both commands indicate that the port is a TTI port,
the abort is correct, and no action is necessary.
FAIL Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS The message to light every station lamp was successfully sent to the port.
1. Observe the station lamps being lit when running the test. If every lamps
does not light, the other Digital Line test results may indicate related
problems that are causing the unlit lamps.
2. Investigate by using other Digital Line port tests and by examining the
station, wiring, and connections.
Table 8-285. Test #16 DIG-LINE Station Lamp Updates Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page