Maintenance-Object Repair Procedures
555-233-143
8-734 Issue 1 May 2002
Station Lamp Updates Test (#16)
This test lights every lamp on the terminal as specified. The lamp updates will run
only if the station is in service. The status of the station is checked and the lamp
updates are blocked from taking place if the station is not in the in-service state.
This test does not affect the status of the Message Waiting lamp.
Table 8-285. Test #16 DIG-LINE Station Lamp Updates Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1 ABORT System technician may have busied out the port.
1. Look for Error Type 18 (port busied out) for this port. If this error type is
present, then release the port (release station extension) and run the test
again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
3 ABORT Station may be in ready-for-service or out-of-service state.
1. Use the status station command to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port is busy
with a valid call.
1. Use display port UUCSSpp to determine the station extension or
attendant number of the port.
2. Use status station or status attendant to determine the service state of
the port. If the port is in use, wait until it is idle before retesting. Attendants
are always in use (off-hook) if the handset is plugged in and the port is not
busied out.
3. Retry the command at 1-minute intervals up to 5 times.
Continued on next page