ETH-PT (Control LAN Ethernet)
Issue 1 May 2002
8-753555-233-143
Table 8-295. Test #1286 Session Status Test
Error
Code
Te s t
Result Description / Recommendation
1124 ABORT Ethernet link is not enabled.
1. Verify that the Ethernet link is enabled (status port UUCSSpp, status
link n, or display data-module).
2. If the link is not enabled, enable the link (change data-module).
3. Repeat the test.
4. Escalate if the problem persists.
1125 ABORT Ethernet link not in service.
1. Verify whether Ethernet link is in service (status port UUCSSpp or
status link n).
2. If the Ethernet link is not in service, release the link (release link n or
release port UUCSSpp).
3. Repeat the test.
4. Escalate if the problem persists.
2000 ABORT Did not receive circuit pack test response within the allowable time period.
1. If the problem persists, reset the circuit pack (busyout board
UUCSSpp, reset board UUCSS, and release board UUCSS).
2. If the problem persists, replace the circuit pack.
2100 ABORT Could not locate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals, up to 5 times.
2. Escalate if the problem persists.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals, up to 3 times.
2. Escalate if the problem persists.
1 FAIL System software indicates at least one Ethernet link session is down (SOME
UP).
1. Isolate downed sessions (status port UUCSSpp or status link n).
2. Follow actions based on session information.
Continued on next page