Maintenance-Object Repair Procedures
555-233-143
8-832 Issue 1 May 2002
Notes:
a. The fiber is in frame, but no communication exists to the neighbor.
b. This is the normal state for an active PN EI circuit pack that is also the bus
master (expansion Archangel) in the PN.
c. This is the normal state for an active EI circuit pack that is not the bus
master (expansion Archangel) for an PN. This applies only in the direct
connect configuration where the EI circuit pack in an PN connects via a
fiber link to an EI circuit pack in the other PN. This state also applies for an
active EI circuit pack located in the PN.
d. This is the normal state for a standby expansion Interface circuit pack in
the PN.
For more details about how the EI circuit pack error codes relate to the LED
states, see ‘‘EXP-INTF (Expansion Interface Circuit Pack)’’ on page 8-762.
Notes:
a. A Fiber is out of frame or a fiber loss-of-signal condition exists.
b. DS1 CONV/fiber endpoint communication is down.
c. The DS1 channel is down between the two DS1 CONVs in the DS1
converter complex.
Table 8-317. Expansion Interface Circuit Pack Amber LED Flashing Codes
Condition LED on LED off
Fiber Out-of-Frame 0.1 second 0.1 second
(a) In frame-No Neighbor 0.5 second 0.5 second
(b) Expansion Interface Active 2 second 0.2 second
(c) Expansion Interface Active Solid on Never off
(d) Expansion Interface Standby Never on Solid off
Table 8-318. DS1 CONV Amber LED Flashing Codes
Condition LED on LED off
(a) Fiber out of Frame 0.1 second 0.1 second
(b) In frame, fiber channel is down 0.5 second 0.5 second
(c) In frame, DS1 channel down 1 second 1 second
(d) DS1 CONV no response from media
server
2 second 0.2 second
DS1 CONV active Solid on Never off
DS1 CONV standby Never on Solid off