EasyManua.ls Logo

Avaya S8700 - Page 1555

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FIBER-LK (Fiber Link)
Issue 1 May 2002
8-833555-233-143
d. The media server is not acknowledging messages from the DS1 CONV
circuit pack or the DS1 CONV circuit pack does not have a processor
route. This pattern indicates a probable software problem.
In addition to the traditional red, green, and amber LEDs, the DS1 CONV circuit
pack has four green LEDs that indicate whether a receive signal is present for
each DS1 facility.
Error Log Entries and Test to Clear Values
Notes:
a. The failure audit test (#777) should be run to confirm whether the error still
exists.
b. This error indicates problem with the control path to the neighbor.
c. This error indicates that the fiber link has been busied out via the busyout
fiber F P command. To resolve this error, release the fiber link with the
release fiber F P command.
d. This error indicates problem with the circuit path to the neighbor.
e. This error indicates problem with the packet path to the neighbor.
Table 8-319. Fiber Link Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0Any Any Anytest fiber-link F P r 1
1 (b) any failure audit (#777) (a) MAJOR, MINOR,
WARNING
OFF test fiber-link F P r 1
18 (c) 0 busyout fiber F P WARNING OFF release fiber F P
257 (d) any failure audit (#777) (a) MAJOR, MINOR,
WARNING
OFF test fiber-link F P r 1
513 (e) any failure audit (#777) (a) MAJOR, MINOR,
WARNING
OFF test fiber-link F P r 1
76 9(f) any failure audit (#777) (a) MAJOR, MINOR,
WARNING
OFF test fiber-link F P r 1
1025 (g) any failure audit (#777) (a) MAJOR, MINOR,
WARNING
OFF test fiber-link F P r 1
1281 (h) any failure audit (#777) (a) MAJOR, MINOR,
WARNING
OFF test fiber-link F P r 1