FIBER-LK (Fiber Link)
Issue 1 May 2002
8-851555-233-143
136 FAIL The Endpoint 1 SNIs administered neighbor does not match the physical
neighbor connected. (The list fiber-link command displays a fiber links
endpoints.) The SNIs assigned neighbor is another SNI, but the SNI is
physically connected to an EI. Enter list fiber-link, and verify that the
fiber-optic and metallic cables are installed as administered.
137 FAIL The Endpoint 1 SNIs administered neighbor does not match the physical
neighbor connected. (The list fiber-link command displays a fiber links
endpoints.) The SNIs assigned neighbor is an EI, but the SNI is physically
connected to another SNI. Enter list fiber-link, and verify that the fiber-optic
and metallic cables are installed as administered.
138 FAIL The physical location of SNI Endpoint 1s neighbor does not match its
administered location. (Enter list fiber-link to display a fiber links endpoints.)
One location (carrier and slot) is assigned for the endpoints neighbor, but it
physically resides in another location.
1. Enter list fiber-link, and verify that the fiber-optic and metallic cables are
installed as administered.
2. If the problem does not seem to be caused by either a physical-connection
or an administration problem, replace the neighbor circuit pack. The
neighbor circuit pack may have a hardware problem causing it to report a
wrong angel address (physical carrier/slot address) to software.
139 FAIL The Endpoint 1 SNI is administered to be connected to a DS1 CONV, but is not
physically connected to one. (The list fiber-link command displays a fiber
links endpoints.)
If a DS1 CONV should be connected to this SNI, enter list fiber-link, and verify
that the fiber-optic and/or metallic cables are installed as assigned.
If not, change administration to remove the DS1 converter complex from the
SNIs fiber link by:
1. Entering list fiber-link to locate the fiber with this SNI as an endpoint
2. Entering remove fiber-link to remove the fiber
3. Entering add fiber-link to add the fiber back, without assigning the DS1
converter complex
Table 8-328. Test #759 Configuration Audit Continued