EasyManua.ls Logo

Avaya S8700 - Page 1617

Avaya S8700
2618 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
H323-SGRP (323 Signaling Group)
Issue 1 May 2002
8-895555-233-143
2000 ABORT Response to the test was not received from the C-LAN circuit pack within the
allowable time period.
1. If this result occurs repeatedly, attempt to reset the circuit pack if the other
ports on the board are idle (amber LED is off). Reset the circuit pack by
issuing the busyout board UUCSS, reset board UUCSS, and release
board UUCSS commands.
2. If this result occurs again, replace the circuit pack.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2100 ABORT The necessary system resources to execute the test could not be allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 3times.
2800 ABORT No C-LAN in the same region.
1. Verify translations and retest.
2801 ABORT No IP address defined.
1. Verify translations and retest.
2802 ABORT Different IP address pinged than software had allocated for the test.
1. Retry the command at 1-minute intervals up to 3 times.
7, 89,
1007
FAIL PING to the destination failed through this port because the destination was
down.
1. Verify that at least one destination reachable through this port is up.
Once verified, execute test sig-group grp# command to verify that the
H.323 Signaling Group Ping test (#1387) passes.
PASS PING through this port was successful.
Table 8-342. Test #1387 H.323 Signaling Group Ping Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page

Table of Contents

Other manuals for Avaya S8700

Related product manuals