Maintenance-Object Repair Procedures
555-233-143
8-896 Issue 1 May 2002
MedPro Status Test (#1392)
This test is nondestructive.
This test determines if at least one media processor port exists that is in service,
and that serves the same region as the C-LAN that the signaling group uses. If at
least one exists and is in service, the test passes; otherwise, the test fails.
Table 8-343. Test #1392 MedPro Status Test
Error
Code
Tes t
Result Description / Recommendation
2100 ABORT The necessary system resources to execute the test could not be allocated.
1. Retry the command at 1-minute intervals up to 5 times.
2500 ABORT Internal system Error.
1. Retry the command at 1-minute intervals up to 3 times
FAIL No MEDPRO ports in this region are in service. Every session is down.
1. Execute test sig-group grp# and verify the result of the H.323 Signaling
Group Ping test (#1387). If the test continues to fail, escalate the problem.
If the test passes, wait for the sessions to come up.
PASS Every session on the ethernet link is up.