Maintenance-Object Repair Procedures
555-233-143
8-930 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Table 8-359. DS1 Interface Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0 Any Any Any test board UUCSS
1(a) 0 Circuit pack removed or
SAKI test (#53)
MIN/WRN OFF
18(b) 0 busyout board UUCSS WARNING OFF release board UUCSS
23(c) 0 Board administered but not
inserted
WARNING OFF add ds1 UUCSS
125(d) none Wrong board MINOR ON
257(e) 65535 Control Channel Loop test
(#52)
MINOR ON test board UUCSS l r
20
513(f) 4352
4353
4355
4356
4358
TN2302 On board hardware
errors
MINOR ON
769(g) 2-Way Transmission tests
(#1505 & 1506)
MINOR OFF
1025(h) Any FPGA Query test (#1406) MINOR
1281(i) Any TSI Health Query test
(#1406)
1538(j) Any Circuit pack is hyperactive MINOR ON
1793 Any NIC Loss Of Signal MIN/
WRN
2
2. Minor alarms on this MO may be downgraded to warning alarms based on values set in the set options
command.
test board UUCSS l r 2
2049(k) Any PPC Sanity Query test
(#1406)
2305(l) Any IP Address Update
2561(m) Ping error
2817(n) Any Ethernet Hardware Query
test (#1406)
3073(o) Any Circuit pack reset test (#53)
3840,
3841(p)
Inconsistent downlink or
board error
3999(q) Any None