Maintenance-Object Repair Procedures
555-233-143
8-994 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. These Error Types indicate a disagreement between this switch and the
switch at the other end of the trunk connection with regard to the ISDN call
state of the DS1 ISDN Trunk. This switch will automatically try to recover
by clearing the call, (that is, call will be torn down). You can use the status
trunk group#/member# command to determine the state of the trunk.
Table 8-392. DS1 ISDN Trunk Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp
1 (a) Any None test port UUCSSpp
15 (b) Any Audit and Update test
(#36)
18 0 busyout trunk
grp/mbr
release trunk grp/mbr
19 (c) 0 None
129 (d) None WARNING OFF test port UUCSSpp
130 (e) None WARNING ON test port UUCSSpp
257 (f) Any None test port UUCSSpp
513 (g) Any None WARNING OFF test port UUCSSpp
769 (f) Any None test port UUCSSpp
1025 (h) 0 None
1281 Any Conference Circuit test
(#7)
MAJOR MINOR
WARNING
2
2. Major or minor alarms may be downgraded to Warning alarms based on the value used in the set options
command.
ON test port UUCSSpp l r 4
1537 Any NPE Crosstalk test
(#6)
MAJOR MINOR
WARNING
2
ON test port UUCSSpp l r 3
1793 (i) Any None test port UUCSSpp
3073 (j) Any Service State audit
(#256)
test port UUCSSpp
3585 (k) Any None none
3841 (l) Any None WARNING OFF None