Maintenance-Object Repair Procedures
555-233-143
8-1000 Issue 1 May 2002
Table 8-395. Test #7 Conference Circuit Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
in use on a valid call. Use status station or status trunk commands to
determine when the port is available for testing.
1004 ABORT The port has been seized by a user for a valid call. Use status station or status
trunk to determine when the port is available for testing.
1. Retry the command at 1-minute intervals up to 5 times.
1018 ABORT Maintenance is disabled on this trunk.
1. Enable maintenance by entering ‘‘y’’ in the ‘‘Maintenance Tests?’’ field on
page 2 of the change trunk-group form.
1020 ABORT The test did not run due to an already existing error on the specific port or a
more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit pack
and attempt to diagnose the already existing error.
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any FAIL The NPE of the tested port did not conference the tones correctly. This will
cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS The port can correctly conference multiple connections. User-reported troubles
on this port should be investigated using other port tests and examining station,
trunk, or external wiring.