ISDN-TRK (DS1 ISDN Trunk)
Issue 1 May 2002
8-1001555-233-143
Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1
interface circuit pack to assure that the trunks translation is correct. The port
audit operation verifies the consistency of the current state of trunk kept in the
DS1 interface circuit pack and in the switch software.
Table 8-396. Test #36 Audit and Update Test
Error
Code
Tes t
Result Description / Recommendation
1018 ABORT Maintenance is disabled on this trunk.
1. Enable maintenance by entering ‘‘y’’ in the ‘‘Maintenance Tests?’’ field on
page 2 of the change trunk-group form.
ABORT Internal system error
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources to run this test.
FAIL Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS Trunk translation has been updated successfully. The current trunk states kept
in the DS1 interface circuit pack and switch software are consistent.
Continued on next page