Maintenance-Object Repair Procedures
555-233-143
8-1070 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Table 8-434. DS1 Interface Circuit Pack Maintenance Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0Any Any Anytest board UUCSS
1(a) 0 Circuit pack removed or
SAKI test (#53)
MINOR
WARNING
2
2. If ports are assigned to the circuit pack, then a minor alarm is raised. If no ports are assigned to the circuit pack,
then a warning alarm is raised. The alarm is raised after the circuit pack has been missing for a period of 15
minutes. Warning alarms are also raised against any ports administered on the circuit pack.
ON
18(b) 0 busyout board UUCSS WARNING OFF release board UUCSS
23(c) 0 WARNING OFF add ds1 UUCSS
125(d) None None MINOR
WARNING
3
3. Minor alarms on this MO may be downgraded to warning alarms based on values set in the set options
command.
ON
257(e) 6553
5
Control Channel Loop
test (#52)
MINOR ON test board UUCSS l r 2
1538(f) Any Hyper activity MINOR
WARNING
3
ON
1793 Any NIC Loss Of Signal MINOR
WARNING
3
test board UUCSS l r 2
2049(g) Any NT PC Failure MINOR
WARNING
3
reset board UUCSS
2305 Any IP Address Inconsistency test board UUCSS l r 2
2561 Any Ping Error MINOR
WARNING
3
test board UUCSS l r 5
3841(h) 4358 Log Only
3999(i) Any None
Continued on next page