Maintenance-Object Repair Procedures
555-233-143
8-1090 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. The data link between the port and the terminal is not operational (i.e., the
port circuitry has detected an off-board problem). Verify that the MET set is
connected and that the EPF (Electronic Power Feed) test passes. If data
transmission problems are experienced, check for defective wiring or a
defective voice terminal, or move terminal electrically closer to the switch
(i.e., reduce the length of the wiring between the terminal and the switch).
If the problem persists, replace the circuit pack. Once the problem is
resolved, the system retires the alarm after a predetermined time delay.
Table 8-447. MET Line Error Log Entries
Error
Type
Aux
Data Associated Test Alarm Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp sh r 1
1 (a) 40987 None
18 (b) 0 busyout port
UUCSSpp
WARNING OFF release port UUCSSpp
130 (c) None WARNING ON test port UUCSSpp sh
257 (d) 40988 None MINOR
WARNING
2
2. Major or Minor alarms MO may be downgraded to Warning alarms based on the values used in the set options
command.
OFF
513 (e) 40965 Hybrid Line Station
Audits test (#61)
WARNING OFF test port UUCSSpp sh r 4
769 Port Diagnostic test
(#35)
MINOR
WARNING
2
ON test port UUCSSpp l r 3
1025 Hybrid and Conf.
Circuits test (#57)
MINOR
WARNING
2
ON test port UUCSSpp l r 3
1537 (f) 40968 None MINOR
WARNING
2
OFF
1793 TDM NPE Crosstalk
test (#6
MINOR
WARNING
2
ON test port UUCSSpp l r 3
2049 (g) 32770
2049 (h) 40967
3840 (i) 40989