Table 8-454. Test #61 MET Line Station Audits Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Internal system error
1 ABORT The test was aborted due to an internal system error during the switchhook
audit.
2 The test was aborted due to an internal system error during the bad scan
inquiry.
3 The test was aborted due to an internal system error during the EPF audit
inquiry.
1. Make sure that the station is not in an out-of-service state.
2. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the station
extension of the port. Use the status station command to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing.
2. If the port status is idle, then retry the command at 1-minute intervals up to
5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
1. Use the display port UUCSSpp command to determine the station
extension of the port. Use the status station command to determine the
service state of the port. If the port is in use, wait until the port is idle
before testing.
2. Retry the command at 1-minute intervals up to 5 times.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The test failed due to an internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page