Maintenance-Object Repair Procedures
555-233-143
8-1152 Issue 1 May 2002
Table 8-473. Test #13 Analog Port Digital Loop-Around Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Internal system error
1. Retry the command at 1-minute intervals up to 3 times.
1000 ABORT The port is in use on a valid ATMS test call.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort and the port is idle on a valid ATMS test call,
escalate the problem. To determine whether the port is in use by an ATMS
test call, enter status station ext where ext is the assigned ATMS
stations number.
1001 ABORT System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 3 times.
1002 ABORT The system could not allocate time slots for the test. The system may be under
heavy traffic conditions, or it may have time slots out-of-service due to
TDM-BUS errors. A system is considered under heavy traffic when the Call
Processing Occupancy is greater than 50% or when the System Management
and the Call Processing Occupancies together exceed 65%. To view the
system occupancy measurements enter the command status system health
on the system technician terminal.
1. If the system has no TDM-BUS errors and is not handling heavy traffic,
repeat the test at 1-minute intervals up to 3 times.
1003 ABORT The system could not allocate a tone receiver for the test. The system may be
oversized for the number of tone detectors present, or some tone detectors
may be out-of-service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up to 3
times.
1004 ABORT The port was seized by a valid ATMS test call.
1. Retry the command at 1-minute intervals up to 3 times.
2. If the test continues to abort and the port is idle on a valid ATMS test call,
escalate the problem. To determine whether the port is in use by an ATMS
test call enter status station ext, where ext is the assigned ATMS
stations number.
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
Continued on next page