M/T-ANL (Maintenance/Test Analog Port)
Issue 1 May 2002
8-1153555-233-143
7 FAIL Conference test failed on the primary information channel.
1. Run the circuit pack tests to check the Tone-Clock (TONE-BD) circuit pack
and the Tone Detector circuit pack via the test board UUCSS command.
2. Resolve any problems that are detected on the Tone-Clock (TONE-BD)
circuit pack or Tone Detector circuit pack. See the section on Tone
Generator circuit pack.
3. If the Tone-Clock and Tone Detector circuit packs are functioning properly,
and the test still fails, replace the Maintenance/Test circuit pack.
14 FAIL The primary information channel is not transmitting properly. User may not
notice any interruption in service or may not be able to use this port.
1. Run the circuit pack tests to check the Tone Generator circuit pack and the
Tone Detector circuit pack using test board UUCSS.
2. Resolve any problems that are detected on the Tone Generator circuit pack
or Tone Detector circuit pack. See the section on Tone Generator circuit
pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning
properly, and the test still fails, replace the Maintenance/Test circuit pack.
PASS The Maintenance/Test analog port analog trunk testing capability is operating
correctly.
Table 8-473. Test #13 Analog Port Digital Loop-Around Test Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page