Maintenance-Object Repair Procedures
555-233-143
8-1250 Issue 1 May 2002
Error Log Entries and Test to Clear Values
Table 8-508. Packet Interface Error Log Entries
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Indicates that an alarm was raised but an associated error was not entered into the hardware error log due to a
momentary overload condition caused by a burst of hardware or software error reports. Run the long test
sequence. Refer to each appropriate test’s description, and follow its recommended procedures.
0Any Any ONtest packet-interface Uc l r 2
1 (a) Any None MAJOR ON reset packet-interface Uc
2
2. A Packet Interface circuit on an active IPSI can only be reset if it has been taken out of service by
background maintenance software. A Packet Interface circuit on a standby IPSI can be reset
independent of its service state.
10 (b) 0 None
50 (c) 0 None
257 (d) Any None MAJOR ON reset packet-interface Uc
513 (e) Any None MAJOR ON reset packet-interface Uc
769 (f) Any Maintenance
Loop-around test
(#886)
MAJOR ON test packet-interface Uc s r
2
1025 (g) Any Private Loop-around
test (#885)
MAJOR ON reset packet-interface Uc
2
1281 (h) Any None MAJOR ON reset packet-interface Uc
2
1537 (i) Any Memory Checksum
test (884)
MINOR ON test packet-interface Uc l r 2
1793 (j) Any Memory Checksum
test (#884)
MINOR ON test packet-interface Uc l r 2
2049 (k) Any None WARNING ON test packet-interface Uc r 25
2305 (l) Any None test packet-interface Uc r 2
2561 (m) Any Active-Standby Peer
Link test (#888)
MINOR OFF test packet-interface Uc s r
2
2817 (n) Any Read and Clear test
(#887)
MINOR/
MAJOR
ON test packet-interface Uc s
3074,
3073,
3072 (o)
Any Maintenance
Loop-around test
(#886)
WARNING OFF test packet-interface Uc s r
2
3585 (p) Any None WARNING OFF reset packet-interface Uc
2
3841 (q) Any None MAJOR OFF reset packet-interface Uc
2