PMS-LINK (Property Management System Link)
Issue 1 May 2002
8-1277555-233-143
Link Retry Test (#215)
This test sends a message to the PMS software process to make a data call to the
extension where the PMS device connects. If the PMS Link is already up, then
this test passes without making any data call.
Table 8-517. Test #215 Link Retry Test
Error
Code
Tes t
Result Description / Recommendation
10, 20 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
30 ABORT Internal system error.
1. Refer back to ‘‘Procedures for Restoring the PMS Link’’ on page 8-1271 for
resolution.
1010 ABORT The PMS Link has been busied out and placed in the out-of-service state.
1. Enter release pms-link command to release the PMS Link from busyout
state.
2. Retry test pms command to execute the test.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The PMS Link CANNOT be established.
1. Refer back to ‘‘Procedures for Restoring the PMS Link’’ on page 8-1271 for
restoring the PMS Link.
PASS The PMS Link is up.
Continued on next page