PPP-PT (Control LAN Packet/Port)
Issue 1 May 2002
8-1315555-233-143
Error Log Entries and Test to Clear Value
Notes:
a. Error Type 001: SCOTCH Synchronous Loop-around test (#1275) failed.
1. Test the port (test port UUCSSpp long).
2. See ‘‘SCOTCH Synchronous Loop-Around Test (#1275)’’ on page
8-1319 for repair procedures.
b. Error Type 257: C-LAN port detected overrun or underrun condition that
may indicate a hardware problem.
1. Test for hardware problem (test port UUCSSpp long).
2. See ‘‘SCOTCH Synchronous Loop-Around Test (#1275)’’ on page
8-1319 for repair procedures to verify repair.
3. Clear the alarm (test port UUCSSpp long clear).
Table 8-527. PPP-PT Error Log Entries
Error Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
0
1
1. Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
tests description, and follow its recommended procedures.
0 Any Any Any test port UUCSSpp s
1 (a) 0 SCOTCH Sync
Looparound test (#1275)
MINOR ON test port UUCSSpp l r 3
257 (b) 0 WARNING OFF
513 (c) 0 MINOR OFF
769 (d) 0 WARNING OFF
1281 (e) 0
1537, 1538 (f) See note Session Status test
(#1286)
MINOR OFF
17931920 (g) See note
23052560 (h) See note
25612816 (h) See note
3329 (i) 35768 TCP/IP Ping test (#1281) WARNING OFF
3585 (j) 0, 1 TDM Loop-around test
(#1285)
MAJOR ON test port UUCSSpp l r 3
Continued on next page