Maintenance-Object Repair Procedures
555-233-143
8-1316 Issue 1 May 2002
c. Error Type 513: PPP link lost end-to-end connectivity.
1. Test for hardware problem (test port UUCSSpp long).
2. Run TDM Loop-around test (#1285), and refer to repair procedures
if there is a hardware problem.
If there is no hardware problem, the switch tries to re-establish PPP
link.
d. Error Type 769: Port received an invalid frame, which
is greater than the maximum length
contains CRC errors
violates the link level protocol.
1. Test the port (test port UUCSSpp long).
2. Refer to TDM Port Loop-around test (#1285) to verify repair.
3. Clear the alarm (test port UUCSSpp long clear).
e. Error Type 1281: System software received an indication that the far end
has requested a disconnect of a session on this link. This is a log-only
error.
f. Error Type 1537, 1538: Some or all port sessions (sockets) are down
1. Test the port (test port UUCSSpp short).
2. See ‘‘Session Status Test (#1286)’’ on page 8-1322 for repair
procedure to verify repair.
g. Error Type 1793-1920: system software received an indication that a
socket was closed due to an error. Error Type indicates the application
associated with this socket.
Aux Data indicates the internal application number.
If the switch indicates that: Then it:
Some of the sessions are down Raises off-board WARNING
Every session is down Raises off-board MINOR alarm
Error Type Application
1793 Unused
1794 DCS
1795 AUDIX
1796 CMS
1797 ISDN Gateway
17981920 Reserved for future