Loading...
Maintenance-Object Repair Procedures
555-233-143
8-1330 Issue 1 May 2002
Link Retry Test (#215)
This test sends a message to the CDR software process to make a data call to the
extension where the CDR output device connects to. If the CDR link is already
up, then this test will be passed without making any data call.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS The CDR link is torn down.
Table 8-536. Test #215 Link Retry Test
Error
Code
Tes t
Result Description / Recommendation
10 ABORT Internal system error.
20 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
30 ABORT Internal system error.
1. See ‘‘Procedures for Restoring the CDR Link’’ for instructions.
1010 ABORT The CDR link has been busied out to out-of-service.
1. Enter release cdr primary | secondary command to release the CDR link
from busyout state.
2. Retry test cdr primary | secondary long command to execute the test.
2012 ABORT Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The CDR link CANNOT be established.
1. See ‘‘Procedures for Restoring the CDR Link’’ for instructions.
PASS The CDR link is up.
Continued on next page
Table 8-535. Test #213 Link Tear Down Test
Error
Code
Tes t
Result Description / Recommendation
Continued on next page