Maintenance-Object Repair Procedures
555-233-143
8-1336 Issue 1 May 2002
Battery Feed Test (or Port Diagnostic test) (#35)
The battery feed chip provides power to the telephone equipment, signaling,
rotary dial pulsing, transmission, and balance. This test checks the signaling and
switchhook capabilities of the battery feed chip by terminating the port, applying
battery and detecting the resulting current.
Table 8-540. Test #35 Battery Feed Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call. This result is also reported for the system’s
Music-On-Hold port when it is off-hook, which it usually is.
1. Enter display port UUCSSpp to determine the station’s extension. Enter
status station extension to determine the service state of the port. If the
port is in use, wait until the port is idle.
2. Retry the command at 1-minute intervals up to 5 times.
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
Use the display port UUCSSpp command to determine the station extension.
Use the status station command to determine the service state of the port. If
the port is in use, wait until the port is idle.
1. Retry the command at 1-minute intervals up to 5 times.
1005 ABORT The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1018 ABORT The test has been disabled via administration. The default for the
Test field
on the change station form is
y.
1. Determine why this field has been set to
n on this station (this may be due
to the ringing application test 48, which can be customer or terminal
disturbing).
2. To enable the test for the particular analog station being tested, enter
change station extension and set the
Test? field on the change
station form to
y.
1392 ABORT This port is currently a TTI port and the test will not execute on it.
1. Verify that the port is a TTI port using either the display port command
(the display shows that the port is a TTI port) or the list config command
(the display shows a
t for the port).
2. If the port is not a TTI port, escalate the problem. If both commands
indicate that the port is a TTI port, the abort is correct for the test, and no
action is necessary.
Continued on next page