RANL-STA (Remote Analog Line (Station) Port
Issue 1 May 2002
8-1337555-233-143
2000 ABORT Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100 ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL The port’s battery feed chip is unable to supply sufficient power to the terminal
equipment. This could be a marginal test, and the terminal equipment may be
operating satisfactorily.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to fail, determine whether the customer is experiencing
problems on this line. Replace the circuit pack only if the customer is
experiencing problems.
PASS The port’s battery feed chip can provide power to the station equipment to
detect on-/off-hook, but may not be able to supply power for touch tones. If
touch tones are inoperative on this station, then replace the circuit pack
because this port is inoperative.
User-reported troubles on this port should be investigated by using other port
tests, by examining station wiring, or by examining the station.
Table 8-540. Test #35 Battery Feed Test — Continued
Error
Code
Tes t
Result Description / Recommendation
Continued on next page