RANL-STA (Remote Analog Line (Station) Port
Issue 1 May 2002
8-1339555-233-143
Station Present Test (or Ringing Application Test)
(#48)
This test applies momentary ringing voltage to the terminal equipment and
monitors resulting current flow to determine whether the terminal equipment is
connected to the port. The test may cause some terminal equipment to ring
briefly during daily maintenance. If this ringing disturbs the customer or the
terminal equipment, disable it via the Tests field on the change station form.
However, on some software releases, Test #35 is disabled.
Table 8-542. Test #48 Station Present Test
Error
Code
Tes t
Result Description / Recommendation
ABORT Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000 ABORT System resources required to run this test are not available. The port may be
busy with a valid call. Use the display port UUCSSpp command to determine
the station extension. Use the status station command to determine the
service state of the port. If the service state indicates that the port is in use.
Wait until the port is idle.
1. Retry the command at 1-minute intervals up to 5 times.
1004 ABORT The port was seized by a valid call during the test, and the test was aborted.
Use the display port UUCSSpp command to determine the station extension.
Use the status station command to determine the service state of the port. If
the service state indicates that the port is in use. Wait until the port is idle.
1. Retry the command at 1-minute intervals up to 5 times.
1005 ABORT The test was aborted due to a configuration problem. This test may not be
applicable, or it may be disruptive to terminal equipment other than a voice
terminal (for example, the modem pool member or Music On Hold).
1008 ABORT Could not allocate a ringing circuit. Either every ringing circuit is in use, or the
ringing generator is either defective or incorrectly wired.
1. Retry the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, look for RING-GEN errors in the Error Log. If
an ABORT 1008 occurs for this test on other circuit packs as well, then the
ringing generator may be defective or incorrectly wired (see errors for
RING-GEN). If it does not occur on other ports, then all four ring phases
are in use.
1018 ABORT The test has been disabled by administration. The default for the
Test field
on the change station form is
y. Determine why this field has been set to n on
this station (this may be due to the brief ringing disturbance that this test may
cause).
1. To enable the test for the particular analog station being tested, enter
change station extension and set the Test? field on the change
station form to
y.
Continued on next page